Electronic Load 250 YA 2kW
Adjustable electronic load with 2 kW capability
Target Specification:
- Up to 2 kW load continuous duty.
- Linear dissipative: no switching noise.
- Up to 250 A at +8 V continuous duty.
- Up to 20 A at +100 V continuous duty.
- Up to 100% power over-range at reduced duty cycle.
- Constant resistance mode: 20 mΩ … 10 Ω in 2 – 5 – 10 steps.
- Constant current mode: 0 … 350 A in one continuous range.
- Residual resistance in “Constant current mode”: max 8 mΩ.
- Disconnect switch: rated -50 V … +120 V.
- Over-temperature protection.
- Over-current protection at 360 A: open disconnect switch.
- Over-voltage protection at 120 V: crowbar type with 600 A capability up to 15 seconds.
- Over-power protection: 4kW instantaneous, derated for SOAR at higher voltage.
- Point of load voltage measurement.
- Voltage monitor output: 1 V/V.
- Current monitor output: 1 mV/A.
- Input connections on front panel: 2 copper bars + 2 BNC connectors for voltage sensing.
- Insulation: all circuitry insulated > 500 VDC from chassis and mains ground.
- Case: 19” 5 unit height.
- Auxiliary power: 230 V +/- 10 % 50 … 60 Hz 35 VA.